This page covers installation on the Cisco Catalyst 9000 switch series. The typical networking mode on this platform is AppGigabitEthernet, the dedicated front-panel port for on-device applications. It supports both access and trunk (VLAN-tagged) configurations.

Validated software

Device Validated IOS-XE
Cisco Catalyst 9000 series 17.18.2

Other IOS-XE versions with App Hosting may work but are not validated.

Device prerequisites

Apply the following IOS-XE config on the switch.

Enable secure gNXI for gNOI software lifecycle

Image upgrade and downgrade additionally require secure gNXI with gNOI and password authentication enabled. An unprovisioned device uses gnxi secure-init as its temporary certificate bootstrap; a device that already has the intended identity instead uses gnxi secure-trustpoint and gnxi secure-server. Do not combine those starting-state command sets, and do not enable gnxi secure-client-auth for a password-only CVK deployment.

Follow the IOS-XE gNOI Upgrade and Downgrade Runbook for the exact device commands, certificate requirements, Kubernetes objects, and post-provision checks.

Enable IOx, RESTCONF, and App Hosting

! Enable IOx (on-device container platform)
iox

! Enable the RESTCONF HTTPS listener
restconf

Keep package signing enabled for signed packages. Only when deliberately using unsigned lab/custom packages, either set spec.allowUnsignedApps: true or configure both device controls below. Confirm the effective runtime state with show app-hosting infra; see package policy.

app-hosting verification disable
no app-hosting signed-verification

Configure the AppGigabitEthernet port

AppGigabitEthernet is the dedicated on-box port for application networking. It is enabled per-switch.

! Enable app-hosting on AppGigabitEthernet port
interface AppGigabitEthernet1/0/1
 switchport mode trunk                 ! or 'access' — see mode details below
 switchport trunk allowed vlan 200     ! only for trunk mode
 no shutdown

Adjust the interface number to your chassis. For trunk mode, create the allowed VLAN interfaces elsewhere in the switch config:

vlan 200
 name app-hosting

interface Vlan200
 ip address 192.168.200.1 255.255.255.0

ip dhcp pool app-hosting-vlan200
 network 192.168.200.0 255.255.255.0
 default-router 192.168.200.1
 dns-server 8.8.8.8

VK configuration

There are two modes for AppGigabitEthernet: access (all traffic on a single VLAN) and trunk (containers on a specific tagged VLAN). Trunk is the more common choice on the Catalyst 9000.

Containers attach to a tagged VLAN on the AppGigabitEthernet port. Use this when you want to isolate container traffic on its own VLAN.

apiVersion: cisco.vk/v1alpha1
kind: CiscoDevice
metadata:
  name: cat9000-1
  namespace: default
spec:
  driver: XE
  address: "192.168.1.100"       # management IP of the switch
  port: 443
  username: admin
  credentialSecretRef:
    name: cat9000-1-creds        # Secret with key: password
  tls:
    enabled: true
    insecureSkipVerify: false
  # allowUnsignedApps: true      # uncomment when running unsigned packages
                                  # — e.g. your own custom application builds.
                                  # See Troubleshooting → PackagePolicyInvalid.
  xe:
    networking:
      interface:
        type: AppGigabitEthernet
        appGigabitEthernet:
          mode: trunk
          vlanIf:
            dhcp: true              # IPs from the VLAN 200 DHCP pool
            vlan: 200
            guestInterface: 0       # container-side eth index (0 = eth0)

The device HTTPS certificate must match its address and be trusted by the worker. For a private CA, use Shared TLS: managed caSecretRef is introduced in v2026.11.1 and requires matching CRDs, admission policies, manager and workers. October v2026.10.0 installations need system trust or an explicit custom CA mount. This app-hosting configuration leaves gNOI in legacy auto mode. Before invoking gNOI, configure explicit verified gNOI TLS.

Mode 2 — Access

Containers land directly on whatever VLAN the switchport is configured with, no tagging. Useful when one port = one flat container network.

spec:
  xe:
    networking:
      interface:
        type: AppGigabitEthernet
        appGigabitEthernet:
          mode: access
          dhcp: true
          guestInterface: 0

AppGigabitEthernet field reference

Field Type Default Notes
mode enum — access or trunk.
dhcp bool false Applies to access mode only when vlanIf.vlan is 0; otherwise use vlanIf.dhcp.
guestInterface uint8 (0–3) 0 Container-side interface index (0 = eth0).
vlanIf.vlan uint16 (0–4094) — App-hosting VLAN ID; a nonzero value uses the VLAN-specific settings in access or trunk mode.
vlanIf.dhcp bool false DHCP for trunk mode and access mode with a nonzero VLAN ID.
vlanIf.guestInterface uint8 (0–3) 0 Container-side interface index on the VLAN.
vlanIf.macForwardingEnabled bool false Pass VLAN MACs into the container (use with care).
vlanIf.multicastEnabled bool false Allow multicast on the VLAN.
vlanIf.mirrorEnabled bool false Mirror the VLAN into the container.

Static IPs (no DHCP)

For the nonzero-VLAN configuration below, setting vlanIf.dhcp: false requires podCIDR, but this is not an address pool allocator. The current implementation assigns only the first container a fixed address derived by adding 10 to the network address's last octet. Separate Pods reuse that address; later containers receive no static address from this calculation. Access mode with VLAN 0 does not receive a static address from this path. Use DHCP for multiple independent workloads. See the canonical static-address limitation.

spec:
  podCIDR: "192.168.200.0/24"   # first container: 192.168.200.10; reused across Pods
  xe:
    networking:
      interface:
        type: AppGigabitEthernet
        appGigabitEthernet:
          mode: trunk
          vlanIf:
            dhcp: false
            vlan: 200
            guestInterface: 0

Verification

On the cluster

kubectl get ciscodevice cat9000-1
# PHASE should reach Ready within ~15s

kubectl get node cat9000-1
# STATUS should be Ready

On the device

ssh admin@192.168.1.100

# Confirm IOx is enabled
show iox-service

# Confirm the AppGigabitEthernet port is up and the right mode
show run interface AppGigabitEthernet1/0/1
show interface AppGigabitEthernet1/0/1

# After a pod is scheduled: see the container
show app-hosting list
show app-hosting detail appid cvk00000_<pod-uid>

The container's application-state should transition through DEPLOYED → ACTIVATED → RUNNING.

RESTCONF reachability (from any host)

curl --cacert /path/to/trusted-device-ca.crt --user admin \
  https://192.168.1.100/restconf/data/Cisco-IOS-XE-native:native/hostname

Other interface modes on Catalyst 9000

The Management interface mode also works on Catalyst 9000 — containers share the management network rather than running on AppGigabitEthernet. See Configuration → Other interface modes.

See also